Solar Controllers Knowledge
Wellsee solar controller WS-C2415 USER’S MANUAL
Written by Raina Xiao Tuesday, 13 July 2010 14:32

Thank you for purchasing our WELLSEE solar controller. Please read these instructions before use.
Our controller named as follow:
WS –C 24 15
| | | |
| | | |________15: maximum current (A), 15= 15A
| | |__________ 24: system voltage (V), 24 =24V/12V automatic recognition
| |_____________ C: solar universal controller
|________________WS= WELLSEE brand
Function:
According to the voltage of the battery, the controller can adjust the charging current and decide whether to supply power to the loads.
- 1. Always keep the battery on full voltage condition.
- 2. Prevent the battery from over-charging.
- 3. Prevent the battery from over-discharging.
- 4. Prevent the battery from reverse charging to solar panels during nights.
- 5. Choose the suitable Wire Diameter according to the current, Please refer to the technical Index for details.
- 6. The solution for the controller can't charged because of the low voltage of battery : please remove the load first, press the bottom RESET to make the controller will reture to work, then charge the battery, in the last place,you can connect the load again.
- 7. If there is some problem with charging the battery, you should increse the power of panel or change the battery
Connection:

As indicated in diagram:
- Connect “+” and “-“poles of the solar panels with the correct terminals on the controller (the first and second from the left).
- Connect”+” and “-“poles of the battery with the correct terminals on the controller (the third and fourth from the left).
- Connect “+” and “-“poles of the load with the correct terminals on the controller (the fifth and sixth from the left).
Indicator light:
There are 3 red LEDs indicate the voltage level of the battery: a red charging indicator light (CHARGE), a green load indicator light (LIGHT), and a battery power indicator light (BATTERY). The battery is full when all 3 LEDs are on. When 1 or 2 LEDs are on, it means the battery is on the low level; in this case the loads may not work normally. As the voltage of the battery reaches 12.6V, the loads will start working automatically.
- The battery is strongly charged when CHARGE is on. The battery is floating charged when this LED is flickering, and the battery has stopped charging when the LED is off.
- When LIGHT is on, it means the load can work; when it’s off, it means the load can not work.
- When BATTERY is red means the battery is under voltage, green means the battery is full and orange means the battery is under normal situation.
Notice:
- Please check the rated voltage of solar panels, battery, and load before connecting. Make sure their rated voltage should be all 12v (or 24v).
- Pay more attention to “+” and “-“poles of solar panels, battery, controller and loads during the process of connection.
- The rated current of solar panels and loads must be lower than the controller.
Technical Index:
|
Model |
WS-C2415 6A |
WS-C2415 10A |
WS-C2415 15A |
|
Rated Voltage |
12V/24V Automatic voltage recognition |
||
|
Max Load current |
6A |
10A |
15A |
|
Input current range |
12V~17V/24V~34V |
||
|
Length≤1m Charge loop drop |
<0.25V |
||
|
Length≤1m Discharge loop drop |
<0.05V |
||
|
Over voltage protection |
17V/34V |
||
|
Full charge cut |
13.7V/27.4V |
||
|
Low voltage cut |
10.5~11V/21V~22V |
||
|
Temperature compensation |
-3mv/℃/cell |
||
|
No load loss |
≤10mA |
||
|
Max wire area |
2.5mm2 |
||
|
Ambient temperature |
-25℃——55℃ |
||